Product Features
ØSingle +3.3V power supply
Ø Support 10GBASE-T
Ø Hot-Pluggable SFP+ Footprint
Ø Compact RJ-45 connector assembly
Ø RJ45 port: 10M/100M/1000M/2.5G/5G/10G full speed, full-duplex mode adaptive
Ø SFP interface: 1000BASE-X/2500BASE-X/5000BASE X/10G-SR, 10G-SR or USXGMII
Ø Zero latency, pass-through mode or store-and-forward mode
Ø 10 Gigabit Ethernet supports Cat6a/Cat7 cables, with Cat6a cables capable of transmitting up to 30 meters.
Ø The standard I2C interface supports switches accessing EEPROM/Register.
Ø Temperature Range:Commercial:0°C ~70°C
Ø Power consumption :2.5W
Ø RoHS compliant and lead-free
Applications
Ø 10GBASE-T Ethernet
Ø Office Network
Description
HC-PP-T-30 10 Gigabit Ethernet module effectively and comprehensively supports 6-speed full-duplex or half-duplex modes. It is stably used in backbone fiber optic switching networks such as supercomputing centers, big data centers, and monitoring rooms, as well as in home and SOHO office networks. It achieves long-distance network cable transmission: 30 meters . Depending on the needs of the application, the HC-PP-T-30's DIP switch mode control, with its SFP interface passive follow mode, effectively solves the matching of various SFP speed interfaces, greatly improving the module's compatibility and application scenarios.
Absolute Maximum Ratings
Table 1-Absolute Maximum Ratings
|
Parameter |
Symbol |
Min |
Max |
Unit |
Note |
|
Storage Temperature |
TS |
-40 |
85 |
°C |
|
|
Operating Case Temperature |
TOP |
0 |
70 |
°C |
|
|
Power Supply Voltage |
VCC |
-0.5 |
3.6 |
V |
|
|
Relative Humidity (non-condensation) |
RH |
0 |
85 |
% |
|
Note:
It has to be noted that the operation in excess of any individual absolute maximum ratings might cause permanent damage to this module.
Recommended Operating Conditions
Table 2-Recommended Operating Conditions
|
Parameter |
Symbol |
Min |
Typical |
Max |
Unit |
Note |
|
Operating Case Temperature |
TOP |
0 |
|
70 |
°C |
|
|
Power Supply Voltage |
VCC |
3.135 |
3.3 |
3.465 |
V |
|
|
Power Consumption |
P |
|
|
2.5 |
W |
|
|
Supply Current |
Icc |
|
|
800 |
mA |
|
|
Aggregate Bit Rate |
BRAVE |
- |
10.3125 |
13.125 |
Gb/s |
|
|
Transmission Distance |
TD |
|
- |
30 |
m |
Over Cat6A |
|
I ²C Clock Rate |
|
0 |
|
200,000 |
Hz |
|
Electrical Characteristics
Table 4-Electrical Characteristics
|
Parameter |
Symbol |
Min. |
Typ. |
Max. |
Unit |
Notes/Conditions |
|
High-Speed Electrical Interface, Transmission Line-SFP |
||||||
|
Supply Current |
Icc |
|
|
800 |
mA |
|
|
Input Voltage |
Vcc |
3.13 |
3.3 |
3.47 |
V |
Referenced to GND |
|
Maximum Voltage |
Vmax |
|
|
4 |
V |
|
|
Surge Current |
Isurge |
|
TBD |
|
mA |
Hot plug above steady statecurrent. See caution notebelow |
|
High-Speed Electrical Interface, Transmission Line-SFP |
||||||
|
Line Frequency |
fL |
|
125 |
|
MHz |
5-level encoding, perIEEE 802.3 |
|
Tx Output Impedance |
Zout,TX |
|
100 |
|
Ohm |
Differential, for allfrequencies between1MHz and 125MHz |
|
Rx Input Impedance |
Zin,RX |
|
100 |
|
Ohm |
Differential, for allfrequencies between1MHz and 125MHz |
|
High-Speed Electrical Interface, Host-SFP |
||||||
|
Single ended data inputswing |
Vinsing |
250 |
|
1200 |
mV |
Single ended |
|
Single ended data outputswing |
Voutsing |
350 |
|
800 |
mV |
Single ended |
|
Rise/Fall Time |
Tr,Tf |
|
175 |
|
psec |
20%-80% |
|
Tx Input Impedance |
Zin |
|
50 |
|
Ohm |
Single ended |
|
Rx Output Impedance |
Zout |
|
50 |
|
Ohm |
Single ended |
Edge connector and pinout description
The electrical pinout of the SFP+ module is shown in Figure below.
|
PIN # |
Name |
Function |
Notes |
|
1 |
VeeT |
Transmitter Ground |
1 |
|
2 |
Tx Fault |
Transmitter Fault - High indicates a fault condition |
2 |
|
3 |
Tx Disable |
Transmitter Disable – High or open disables the transmitter |
|
|
4 |
SDL |
2-wire Serial Interface Data Line (MOD-DEF2) |
3 |
|
5 |
SCL |
2-wire Serial Interface Clock (MOD-DEF1) |
3 |
|
6 |
MOD-ABS |
Module Absent, connected to VeeT or VeeR in the module |
|
|
7 |
RS0 |
Rate Select 0 |
5 |
|
8 |
RX_LOS |
Receiver Loss of Signal(LVTTL-O). Logic 0 indicates normal operation |
4 |
|
9 |
RS1 |
Rate Select 1 |
1 |
|
10 |
VeeR |
Receiver Ground |
1 |
|
11 |
VeeR |
Receiver Ground |
1 |
|
12 |
RD- |
Inverse Received Data out (CML-O), AC Coupled |
|
|
13 |
RD+ |
Receiver Non-inverted DATA out. AC Coupled |
|
|
14 |
VeeR |
Receiver Ground |
1 |
|
15 |
VccR |
Receiver Power Supply |
|
|
16 |
VccT |
Transmitter Power Supply |
|
|
17 |
VeeT |
Transmitter Ground |
1 |
|
18 |
TD+ |
Transmitter Non-Inverted DATA in. AC Coupled. |
|
|
19 |
TD- |
Transmitter Inverted DATA in. AC Coupled. |
|
|
20 |
VeeT |
Transmitter Ground |
1 |